"R-value" signifies the ability of a material to resist heat flow. The higher the R-value, the greater the heat flow resistance. For instance, it's more difficult for heat to pass through R-19 insulation than it is to pass through R-11 insulation.
Some materials are naturally better insulators than others. For example, a six-inch batt of fiberglass insulation has an R-value of 19, while an eight-inch concrete block has an R-value of 1.04. Glass, like concrete block, also has little resistance to heat – a single pane of glass has an R-value of 1.13.
The following chart shows average R-values per inch of common insulating materials. Using this chart, you can determine the R-value of a particular amount of insulation from its thickness. For example, 8.5 inches of loose-fill mineral fiber insulation equals R-19. Because R-values per inch vary greatly between different insulating materials, always rate insulation by its R-value and not by inches.
|
|
|
R-Values Per Inch For Common Insulating Materials*
|
| Insulating Material |
Avg. R-Value Per Inch |
| Batts or Blankets |
- Mineral fiber (rock, slag or glass)
|
3.25 |
|
Loose Fill
|
- Mineral fiber (rock, slag or glass)
|
2.2 |
- Cellulose (milled paper and wood pulp)
|
3.4 |
|
2.13 |
|
2.7 |
| Rigid Board and Slabs |
- Expanded polystyrene, extruded (cut-cell surface)
and molded bead-type
|
4.0 |
- Expanded polystyrene, extruded (smooth-cell
surface)
|
5.0 |
- Expanded polyurethane, refrigerant 31 exp.
|
6.25 |
|
7.04 |
| Building Board Sheathing, regular density |
2.64 |
NOTE: Styrene and urethane foams may present smoke- and flame-spread problems if improperly used. Look for UL approval for cellulose. Untreated cellulose is highly flammable.
* R-values from the ASHRAE Fundamentals Handbook. The values given are average R-values. If needed, ask insulation manufacturers for the R-values of insulating materials not listed above.
|
|
|
|
The table below lists R-values for commonly available thicknesses of residential ceiling, wall and floor insulation:
| Insulation Type |
Inches Needed For: |
| Ceiling Insulation |
R-11 |
R-19 |
R-22 |
R-26 |
R-30 |
| Batts or Blankets |
- Mineral fiber (rock, slag, glass)
|
3.5 |
6 |
6.5 |
8 |
9 |
| Loose Fill |
- Mineral fiber (rock, slag, glass)
|
5 |
8.6 |
10 |
12 |
13.6 |
|
|
3.2 |
5.6 |
6.5 |
7.6 |
8.8 |
| Frame Wall Insulation |
R-11 |
R-19 |
|
| Batts or Blankets |
- Mineral fiber (rock, slag, glass)
|
3.5 |
6 |
|
| CBS Wall Insulation |
R-3 |
R-5 |
|
| Batts or Blankets |
- Mineral fiber (rock, slag, glass)
|
.75 |
1.5 |
|
| Rigid Board |
|
|
.5 |
.75 * |
|
- Expanded Polystyrene (molded bead-type)
|
1.0 |
1.5 |
|
Floor Insulation (suspended
frame floors only) |
R-7 |
R-11 |
R-19 |
|
| Batts or Blankets |
- Mineral fiber (rock, slag, glass)
|
2 |
3.5 |
6 |
|
| *.50 with 3/4" dead air space |
Progress Energy's minimum recommendations for house insulation:
- In Florida:
- Ceiling: R-19 to R-30
- Wall: R-11 in frame walls, R-5 in CBS walls
- Floor: R-11 in floors (suspended frame only)
|
|
|

|
|
 |