Skip to Content go to search
Customer Service About Us About Energy Environment Community Investors
Search - click to the Search section
Progress Energy - click to the home page Sun setting behind rows of transmission line towers
En Español    
home > about energy > transmission enhancements > transmission enhancements carolinas > apex - rtp transmission project
Apex-RTP transmission line project
 
 
 
Storm Central
Balanced solution - Carolinas
Balanced solution - Florida
Learning Center
Power Plants
Transmission Enhancements
Transmission Enhancements Carolinas
Apex - RTP Transmission Project
Asheboro - Pleasant Garden Project
Asheville - Enka Transmission Line Project
Cape Fear - Siler City Line
Greenville-Kinston Transmission Project
Henderson-Henderson North Line
Lee - Mt. Olive - Clinton Line
Richmond - Cumberland
Richmond-Rockingham Transmission Project
Rockingham-Lilesville Transmission Project
Rockingham-Wadesboro Transmission Project
Rockingham-West End Transmission Project
Warrenton Transmission Project
Transmission Enhancements Florida
Florida Energy Planning
Coverage Areas
Power Quality & Reliability
Electric Rates
FERC Matters
 
 

Background

Population and energy usage continue to increase in the Triangle region, and plans indicate that significant additional development (e.g., Amberly and other residential subdivisions as well as commercial tracts) is expected for the region. Today, the electric transmission system that serves the region is constrained under certain conditions.

Progress Energy's continuous assessment of electric system requirements had earlier identified the need for enhancements to help ensure a continued reliable supply of electric service to homes and businesses. Portions of the western Wake County transmission project were announced and commenced in 2001, and some transmission improvements have already occurred in this corridor.

Late in 2006, the N.C. Transmission Planning Collaborative issued a preliminary report that confirmed the need for additional improvements and upgrades in this region to enhance electric system reliability and to promote enhanced transmission access across the state. The transmission study group includes representatives from Progress Energy, Duke, the state's electric cooperatives, municipally owned electric systems and an independent third party. The changes adopted by the Planning Collaborative include an upgrade of the facilities between the Harris Nuclear Plant and a substation at RTP from 115 kilovolts to 230 kV.

Therefore, Progress Energy plans to invest an estimated $37 million in building a series of 230-kV transmission lines (approximately 22 miles total), and making other system upgrades, between a substation south of Apex and another in Research Triangle Park. A portion of the existing transmission system between Apex and Green Level will be upgraded to accommodate higher-voltage power lines. And easements acquired initially to accommodate a 115-kV transmission line will be used for the 230-kV line.

Project Description

The project includes four major segments:

  • The southernmost portion of the line, between the Harris Plant switching station (next to the plant) and the Apex U.S. 1 substation, spans about 4 miles and will be built almost entirely on Progress Energy property. It is scheduled to be in service in mid-2011.

  • The length from the Apex U.S. 1 substation to a substation in Green Level was built at 115 kiloVolts and put into operation in 2003. As the area's strong growth continues, the state Transmission Planning Collaborative confirmed that the completed 115-kV portion must be upgraded to 230 kV to increase system reliability. This will necessitate taking down the existing line (approximately 7.5 miles) beginning in late 2010 and building a new line on the same right of way. The new 230-kV line will require taller poles (approximately 100-110 feet above ground versus 80-foot height currently) set into concrete foundations. The Green Level 115-to-23-kV distribution substation also will be upgraded to a 230-to-23-kV distribution substation. This will not require expansion of the substation. This portion must be completed by mid-2011.

  • An approximately 4-mile stretch between the planned Amberly 230-to-23-kV substation and a substation at Research Triangle Park must be in service by mid-2009, including the new Amberly substation. Progress Energy currently has acquired most of the easements required for this portion (since this portion of the line has been planned for several years). The vast majority of this segment will parallel Highway 540.

  • Approximately 7 miles between the Green Level substation and the planned Amberly substation (scheduled for completion in mid-2011). The Green Level-to-Amberly portion of the line is planned for an already reserved transmission corridor. Progress Energy has not yet begun building that portion of the line, but has acquired the majority of easements needed from property owners. On this portion and the Amberly-to-RTP portion, initial easements were negotiated at 115 kV, and many property owners likely will point to that fact. But the easement agreement stipulates that the facility size can be changed. And planning information, confirmed by the Transmission Planning Collaborative, confirms this line now needs to be built at 230 kV.

Why The Project Is Needed:

  • Two decades ago, this part of western Wake County was primarily farm and forest land. Since that time, however, the region has grown at a significant rate - with substantial additional development planned - and the electric system must keep pace. In addition to building new power plants, Progress Energy must continually enhance the transmission and distribution systems to help ensure a continuous, reliable flow of electricity to homes and businesses in the region and to provide adequate import and export capability for wholesale power through Progress Energy's service area, as required by law.
  • The need for the investment and upgrade to 230 kV was confirmed in a recent report by the N.C. Transmission Planning Collaborative, a group of transmission owners, city-owned utilities, electric cooperatives and independent third parties appointed to develop a collaborative planning process to enhance the reliability of the state's transmission system and increase import capability.
  • Without the transmission system upgrades, this rapid-growth area would exceed electric system capability in the near future, potentially creating the types of electric system reliability concerns that have plagued other parts of the country in recent years.
  • Electricity is far too important for our customers to risk service interruptions or problems with power quality due to inadequate facilities. Progress Energy and the N.C. Utilities Commission have an obligation to ensure that the electric system is maintained and upgraded appropriately.
  • High-tech companies and today's highly electronic homes and businesses need reliable, high-quality electricity. This project is intended to ensure the continuation of a reliable, high-quality flow of electricity in the future.
  • The upgrades will enhance system reliability for electricity consumers throughout the region, not just Progress Energy customers.

Additional Benefits:

The transmission upgrades, when complete, are expected to generate more than $109,000 per year in Wake County in additional annual property tax revenues.

Maintaining a robust system for supplying and delivering electricity is integral in ensuring the continued economic prosperity of the region.

The additional transmission system investment will improve power quality and reliability in the area.

Schedule:

The project is expected to be built in two phases, with construction occurring concurrently in several areas: A 4-mile stretch between the planned Amberly substation and a substation at Research Triangle Park will go in service in 2009. The remaining portions are expected to be built by mid-2011, moving generally from north to south. A 7.5-mile portion of the route was built several years ago at 115 kiloVolts, so property easements are already established. That portion will be taken down and rebuilt at 230 kV (using the same easement). The portions between the Green Level substation and the Amberly substation, and from Amberly to the RTP substation, will be built on a corridor already identified but not yet in use. Progress Energy has been acquiring easements from property owners along those routes.

Easement acquisition for the Green Level-Amberly and Amberly-RTP portions has been under way for some time. Construction of the Amberly-RTP 230-kV line section will begin in 2008. Construction of the other portions of the line will begin in 2010.

Permit Requirements:

The project requires a number of local, state and federal permits and approvals, including need certificates from the NCUC, environmental and construction permits. Progress Energy will work with local governments and agencies to ensure that the project complements local growth plans. Progress Energy will comply with all regulatory requirements related to the construction and operation of the facilities. Before the development of any preliminary routes, Progress Energy will contact the Corps of Engineers, the Fish & Wildlife Service, State Historic Presentation officer, the N.C. Department of Environment & Natural Resources and other agencies that have an interest in the project.

Public Participation:

Progress Energy believes public participation is critical to the success of any project. Among other communication initiatives, the company expects to hold public information meetings in the area to be served by the transmission facilities. The purpose of these meetings, scheduled July 31 and Aug. 2, is to provide information on the need, scope and schedule of the project, and to answer questions the participants may have. The N.C. Utilities Commission also may hold a public hearing as part of its review process. Progress Energy also will make information available via the Web and will communicate directly with impacted property owners and others.

Land Acquisition:

Most of the easements needed to accommodate the project have been acquired. On those few portions where easements are not yet acquired, Progress Energy land agents will work individually with property owners in purchasing easements for the facilities. The line will require 35 feet, or slightly more, of right of way on both sides (70-foot total easement requirement). Progress Energy pays fair value for easements, and landowners retain ownership of the property. Progress Energy also will negotiate the right to cut trees off the right of way that could jeopardize the safe operation of the line. Progress Energy does not expect to need to expand the easements already purchased to accommodate a larger transmission line.

Overhead Versus Underground

Progress Energy investigated the possibility of putting portions of the line underground. Underground transmission lines have pros and cons. The reliability of underground transmission lines remains a question across the United States, as relatively few have been constructed. A fault in a buried line, caused by a manufacturing defect or an accidental dig-in, would take much longer to locate and repair than a similar fault in an overhead line. Other adverse factors regarding underground transmission lines are the effects they can have on wetlands and soil erosion and the decreased electrical capacity they can carry. They also tend to be significantly more expensive than overhead lines, and despite the common misperception that underground lines are out of sight, out of mind, their installation is often more environmentally intrusive than overhead construction.

Why Is This Line Now Being Rebuilt At 230-KV?

Progress Energy announced the transmission upgrade in 2001 and began work on various segments at that time. One segment, between the Apex U.S. 1 substation and a substation at Green Level, was completed at 115 kV in 2004. Rapid growth continues in the area. Meanwhile, the N.C. Transmission Planning Collaborative recently identified a 230-kV line between Apex and RTP as a priority for the state to enhance North Carolina's gridwide reliability. Therefore, the entire span of approximately 22 miles, including the portion previously built at 115 kV, will be upgraded to 230 kV.